Steemer Express 100% Guarantee

A Veteran Owned Company

HVAC Cleaning

Indoor air quality is one the most important aspects that a homeowner should look into upon ensuring healthy living conditions inside the home. Some studies reveal that home indoor air has just the same or higher level of pollution as outdoor air has. This alarming fact signals you as the homeowner to take proper measures to ensure premium indoor air quality is enjoyed by your family.

Get Estimate


The SteamWorx Difference – HEPA-AIRE Portable Power Vac

The HEPA-AIRE process utilizes an Abatement HEPA-AIRE Portable Power Vac in tandem with a specially designed AIRE-SWEEP Portable Air Compressor and Agitation Tools for efficient state-of-the-art source removal duct cleaning. This method enables SteamWorx Cleaners to remove contaminants from all parts of the duct system, regardless of location or type of duct.

Here’s how it works:

  1. The supply and return networks are “zoned,” or separated, so they can be cleaned independently. This is typically done by removing the furnace filter, inserting it into a plastic bag and reinserting it into the furnace.
  2. An access hole is cut into the supply plenum and the flex duct from the HEPA-AIRE Vacuum inlet is connected to the plenum with a quick-connect attachment collar. The powerful vacuum creates high velocity air movement within the supply ductwork to transport loosened dirt and contaminants out of the ductwork and into the vacuum’s filtration/collection system.
  3. Each branch is cleaned separately starting with the branch farthest from the vacuum. The register and boot areas are blasted with compressed air from the AIRE-SWEEP Compressor using the special air booster gun to push any dirt or debris into the branch run.
  4. The branches are then cleaned by feeding the Forward AIRE-SWEEP Assembly down each branch run to push dirt and debris forward into the main run. The Reverse AIRE-SWEEP Assembly can also be used to clean branch runs if access at the main supply duct is available.
  5. Agitation devices such as the AIRE-SWEEP Power Brush, Duct Whip or Power Rod System are used when needed to dislodge caked on debris from inside duct surfaces.
  6. The main duct run is then cleaned. First, one-inch diameter access holes must be cut into the duct every 25 feet. Then, the Agitation Devices and an AIRE-SWEEP Assembly are used to dislodge debris accumulated on surfaces. The loosened debris is pulled or pushed toward the HEPA-AIRE Portable Power Vacuum and captured in its multi-stage filtration/collection system.
  7. Once the supply side of the system has been completely cleaned, the return duct system is cleaned using the same method.
  8. The coil, motor and blower and blower compartment can be cleaned.
  9. Once the entire cleaning process is completed, all access holes are completely closed with the efficient CAPLUGSĀ® and cover plates are installed over the access holes.

See Our Specials
SteamWorx